Decade counter with 7 segment output

using the part in-scene § part parameters

 

Using the part in-scene

Useful facts

  • The outputs "a" to "g" on the decade counter should be connected via resistors to the corresponding terminals of a 7-segment display.

 

  • "DEO", the display enable output, mirrors the logic value of the display enable input, but can be used to affect the display of further counters.

 

  • The carry-out pin, "CO", is an output; it can be used to cascade counters together. The carry-out pin will be high when the count is between 0 and 4, and low from 5 to 9.

 

  • The clock inhibit input, "CI", should be at '0' to enable counting.

 

  • The clock input, ">", drives the count with its the positive edge (the '0' to '1' change).

 

  • The display enable input, "DEI", should be at '1' to show the result of the count.

 

  • While the reset pin, "R", is high the counter will ignore any clock inputs and reset the count to zero.

 

 

 

 

 

Part Parameters

This part is based on the 4026B decade counter. Other parameters vary according to the logic family selected in the scene's Properties pane (Electronics):

 

 

74HC

4000B

  • (Hidden) supply voltage (VDD)

2-6V

3-15V

  • Output drive current (IO)

4mA

0.4mA

  • Maximum output (low voltage)

0.4V (IO=4mA)

0.4V (IO=0.4mA)

  • Minimum output (high voltage (VDD=5V))

0.4V (IO=4mA)

0.4V (IO=0.4mA)

  • Maximum voltage (for '0' input)

30% of VDD

30% of VDD

  • Minimum voltage (for '1' input)

70% of VDD

70% of VDD

  • Maximum output current

50mA

50mA

  • Minimum input voltage

-1V

-1V

  • Maximum input voltage

VDD + 1V

VDD + 1V

 

To ensure that an input voltage to a logic IC is recognised as a binary value, it must meet the above-specified Maximum voltage (for '0' input) or Minimum voltage (for '1' output), otherwise the input will have an undefined logic value.